01
Dec
small air output and high noise, temperature deviation, water leakage, and motor does not rotate.
1. The air output of the fan coil is small and the cooling capacity is poor:
When the fan is running normally, in addition to the small air inlet volume and... read more
07
Apr
With the acceleration of urbanization, the number of construction sites is increasing day by day. However, the dust generated during the construction process at these construction sites poses a serious threat to the health of surrounding residents.
To meet this challenge, ZIBO DECENT Machinery proposed... read more
21
Nov
When testing the fan, read the product manual carefully and check whether the wiring mode is consistent with the wiring diagram; carefully check whether the working voltage of the fan power supply meets the requirements, whether the power supply is out of phase or... read more
25
Oct
Whenever the heating season arrives, most areas in the north will be accompanied by smog. Since the “13th Five-Year Plan”, the central and local governments have paid special attention to the control of environmental pollution, especially smog. The central government has demarcated the Beijing-Tianjin-Hebei air pollution transmission channel for it and directly subsidized the “2+26” cities from the central government to control smog pollution. So the north began the tide of coal-to-electricity and coal-to-clean energy.
Two or three years ago, most people didn’t know much about air-to-air heat pump products. If they were slightly impressed, they might be air-to-water heaters, but they didn’t know anything about other products. Such as air-energy floor heating and air-conditioning integrated machine, air-energy heat pump dryer, and so on. After the popularization of “coal-to-electricity” in the north, most people know what an air energy heat pump is. So what is the difference between the ultra-low temperature air energy heat pump used in the north and the ordinary air energy heat pump?
The operating conditions of the two are different.
We all know that the working principle of the air energy heat pump is to convert the heat in the air into the available high heat energy through the compressor, and then exchange it with the water system to provide hot water, heating, cooling, drying, and other purposes. The temperature environment in which the ordinary air source heat pump operates is preferably within minus 10 ℃. If it operates at minus 10 to 25 ℃, it may appear:
1. Compressor is prone to failure
The temperature of the exhaust gas rises rapidly, and the overheating of the working medium is too high. In the case of overheating of the working medium, the thermal conductivity of the working medium in the condenser decreases sharply, and at the same time, the temperature of the lubricating oil increases and the viscosity decreases, which affects the normal lubrication of the compressor.
2. The unit cannot defrost
In frequent rain and snow weather and low temperature, the defrosting ability of the unit is easily weakened. Because the air intake of the unit is too small, the density of the air that can be inhaled is reduced. With the accumulation of time, the thickness of the frost layer is getting higher and higher. Therefore, the unit will reduce the circulation of the refrigerant due to the decrease in the air conversion capacity, and the overall heating capacity will decrease.
The two technologies involved are different
Because of the difference in an ambient temperature between the north and the south, most air energy heat pump manufacturers are located in the southern Guangdong area. The air energy market in the south is extensive. The earliest product is also an air energy water heater. With the development of air energy, its technology is also becoming more and more mature. Heating has also gained a firm foothold in the north, which is also the fundamental reason for the breakthrough growth of coal-to-electricity air-energy heat pumps in the north in the past three years.
So what kind of technology does low-temperature air energy have to gain a firm foothold in the cold northern regions? There are three main points:
1. Ultra-low Temperature air Energy Operation Technology Air energy heat pump manufacturers have their own ultra-low temperature technology. Since the air energy heat pump host is generally installed outdoors, the phenomenon of frost will frequently occur in rainy and snowy weather. The ultra-low temperature air energy heat pump host can intelligently judge the defrosting needs, and intelligently judge whether to defrost according to the operating conditions of the unit (running time, exhaust temperature, etc.), combined with the ambient temperature and frost thickness. Defrost with frost and no defrost without frost, greatly extending the defrosting cycle, shortening the defrosting time by 20%, and ensuring the efficient operation of the unit.
2. Jet Enthalpy Technology
Because the heating efficiency of the air-energy heat pump in extremely cold weather will be greatly attenuated, resulting in an unsatisfactory heating effect. The ultra-low temperature air energy heat pump uses the jet enthalpy increase technology to create a second suction port on the scroll, and through the second suction circuit, the refrigerant flow is increased, and the circulation volume of the unit is increased during cooling. Compared with the general unit, the cooling capacity is increased by 10%, which greatly improves the refrigerant circulation system, makes full use of the refrigerant flow and utilization rate in the compressor, and improves the stability of the system operation and the heating efficiency.
3. Shell and Tube Heat Exchanger
Ordinary air can use a plate heat exchanger, which is easy to scale and block the flow passage. Low-temperature air can use copper tubes with internal thread and external fins. The water inside the tube and fluorine outside the tube. The heat exchange area is large and the heat exchange efficiency is high.
read more
24
Nov
Tall space buildings have special requirements for air conditioning, due to the high space of tall buildings, large floor area, air conditioning airflow organization design has brought a lot of problems: when the need to send cold air in the summer, it is even... read more
03
May
In explosion protection certification, hazardous areas are classified into explosive gas environments and combustible dust environments based on the different states of materials present in the location. Depending on the duration of the presence of hazardous materials in the area, the hazardous areas in... read more
04
Jul
To ensure that the AHU (Air Handling Unit) complies with factory inspection standards, we conduct the following detailed tests before the unit is delivered and provide corresponding test reports. The equipment required for the testing process includes:
Airflow measurement instruments
Air pressure measurement instruments
Noise testing device
Differential... read more
21
Apr
Fog cannons have emerged as a versatile solution for various applications, including pollutant control, dust control on construction sites, and fire extinguishing in storage yards. The technology is gaining popularity due to its effectiveness in mitigating environmental and safety hazards.
In pollutant control, fog cannons... read more
12
Jan
Are you tired of dealing with the uncertainty and stress of international trade? Look no further. Our company specializes in providing comprehensive solutions to the most common concerns of our customers in international trade.
We understand that the logistics of international shipping can be complicated... read more
22
Jan
In a bid to enhance the working environment at a sand and stone plant, Indonesian customers have recently acquired an advanced 80-meter dust reduction fog cannon from our esteemed company. The cutting-edge technology has been strategically placed on a towering structure to efficiently tackle... read more