DK40 Double (Twin) Motor primary Mine Ventilation Booster Fans

DK40 Double (Twin) Motor primary Mine Ventilation Booster Fans

  • Description
  • Inquiry

DK40 Double (Twin) Motor Mine Ventilation Booster Fans

DK40 primary mine fan

DK40 primary mine fan

DK40 mine ventilation booster fan is a primary fan that is in series with another primary fan.

Without the booster fan operation, the total mine airflow will fall significantly. Booster fans are typically installed as mine develops and primary fan no longer has the pressure or flow capability to service increased resistance of operation.

In this sense, booster fan operates as an integral and “symbiotic” unit with the original primary fan to provide sufficient total airflow for mine.

DK40 Double (Twin) Motor primary Mine Ventilation Booster Fans Mine booster fans are technically main fans which are installed underground to maintain required airflow by overcoming the mine resistance.

DK40 primary mine fan

DK40 Double Motor Main Fan
Model No. Speed r/min Airflowm3/s Full Pressure Pa Motor Power(kW)
1500 980 18.2~43.6 382~1690 2×37
1600 980 22.1~52.9 435~1923 2×55
1700 980 26.5~63.5 491~2171 2×75
1800 980 31.5~75.4 551~2433 2×90
730 23.5~56.1 306~1350 2×37
1900 980 37.0~88.6 614~2711 2×132
730 27.6~66.0 341~1504 2×55

Contact Us