Wind system optimization solution for green development of cement industry

Judging from the transformation effect, after the fan system transformation, the fan’s output has been increased and the fan’s energy consumption has been reduced. The power saving rate of the fan system is about 10% to 28%, and some parts reach about 45%. Necessary upgrading and transformation can not only improve production efficiency but also be an essential choice for carbon reduction in the cement industry. In addition to the existing
Upgrading and transforming fans, Decent Machinery’s main fan products are also widely used in the cement industry and have been highly recognized by the owners.
Taking the single-stage high-speed centrifugal blower as an example, the device adopts IGV + DV double guide vane control. Under constant speed operation, the flow rate can be adjusted within the range of 40% to 100% of the design working conditions, and the maximum efficiency of the impeller can reach 95%, ensuring that the unit is Highly efficient operation. Replace single-stage high-speed centrifuge with single-point control.
Blowers, multistage centrifugal blowers, and Roots blowers can realize the efficient operation of the wind system without any adjustments to the wind system.