Small Resistance 99.99% Mine Bag Vacuum Cleaner 1.2m3/min SGS ISO

Small Resistance 99.99% Mine Bag Vacuum Cleaner 1.2m3/min SGS ISO

details :

Source: China
Brand stuff: DECENT MACHINERY
Certifications: SGS ISO CE
Model Number: PPC32-4

Payment:

Minimum order quantity: Negotiate
Price: Negitionable
Packing details: Plastic film inner packing, export special wooden box outside packing.
Delivery time: 30 days after receiving the payment
Terms of payment: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Ability to provide: 100 sets/sets per month

 

Category:
  • Description
  • Inquiry

1.2-2.0/min 8900m3/h Pulse jet vacuum cleaner

Product Description

Industrial vacuum cleaner is a small vacuum cleaner. It adopts cylindrical filter bag, separate fan system, pulse jet ash removal mode, has high purification efficiency, good ash removal efficiency, electrical resistance Small size, long life of filter bag, easy maintenance and safe and reliable operation.

 

 

Widely used in metallurgy, building materials, machinery, chemical industry, mining, etc. all kinds of dust and recycling material filtration process systems.

 

 

Two series of dust filters of twelve specifications, each of which can be divided into standard with type A ash bucket and type B open flange (without ash bucket, applicable to warehouses).

Technical parameters

paradigm PPC32-3 PPC32-4 PPC32-5 PPC32-6 PPC64-4 PPC64-5 PPC64-6 PPC64-7 PPC64-8
Air handling (m3/h) 6900 8900 11160 13390 17800 22300 26700 31200 35700
Filter wind speed (m/min) 1.2-2.0 (select different filter air speeds according to different dust spots)
Total filter area (m2) ninety three 124 155 186 248 310 372 434 496
Filter net area (m2) 62 ninety three 124 155 186 248 310 372 434
Number of vacuum cleaners (units) 3 4 5 6 4 5 6 7 8
Total number of filter bags (sticks) (pcs) 96 128 160 192 256 320 384 448 512
Dust resistance (Pa) 1470-1770
The dust collector is subjected to negative pressure (Pa) 5000
Concentration of imported gas dust (g/m3) <200 <1000
Concentration of flue gas dust (g/m3) <0.1
Ash Pressure
Shrink Air
Pressure (Pa) (5-7) × 105
Air Consumption (m3/min) 0.27 0.37 0.46 0.55 1.2 1.5 1.8 2.1 2.4
Pulse valve amount of money) 3 4 5 6 4 5 6 7 8
Specifications (inches) 1-1 / 2 2-1 / 2
Poppet valve
(with cylinder)
amount of money) 3 4 5 6 4 5 6 7 8
Specification (mm) Lift valve plate diameter 460, cylinder diameter Φ63 Lift valve plate diameter Φ595, cylinder diameter 100
YJD-16 . star loading and unloading equipment Feed port 300×300, height 400mm, speed 41r/min, gear motor power 1.5kW, output 39.4m3/h
Screw Conveyor specifying No
N / A
Diameter 300, capacity 30m3/h (fill rate = 0.7)
Box Reduce speed No
N / A
Model XWD2.2-5-1/59, capacity 2.2kW
Specifications and filter bag material Diameter × length 130 × 2450, polyester needle felt weight 450g/m2, use temperature 120°C
Insulation area (m2) 26.5 34 41 48.5 70 ninety four 118 124 166
Total weight of the device (approximate value) (Kg) 3110 4400 5700 7000 8940 10750 12570 14380 16200

 

Note:

1.The net filter area in the table refers to the filtration area when a room is cleaned. The total weight of the unit does not include the weight of the insulation.
2. The gas consumption in the table refers to the centralized gas supply situation in the plant. If a separate air compressor is installed, the air consumption in the table is multiplied by 1.3.

rules of work

PPC series air box pulse bag filter is composed of upper box body, middle box body, lower box and ash head, ladder, platform, air tank, pulse valve, dragon frame, loading screw, ash unloading valve, electric control cabinet , air press and other components are made as standard. The wiring position of the incoming terminal is set according to the user’s requirements. For the wiring terminal, see the user manual. of the electrical controller.
Under the action of the main fan of the system, the dust-containing gas enters the pre-collection chamber of the dust extraction device from the dust extraction port of the PPC air box bag filter. The dust-containing gas flows into the ash hopper under the action of the dust collector. baffle, and at the same time the flow rate is reduced.Slowly, under the action of inertia and the weight of the dust, the coarser dust particles directly fall into the ash hopper and are discharged from the ash discharging mechanism, playing a role Pre-collection role.Clean air, after passing through the filter bag, enters the upper box, flows into the louver and is discharged outside.
The body of the air box pulse bag filter is divided into several box areas and there is a lifting penalty controlled by a cylinder on the side outlet pipe of each box. When the filter bag of the air box pulse filter is active operating for one cycle, the ash cleaning controller sends a signal, the poppet valve of the first box room starts to close and cut off the overflow, and the pulse valve of the chamber box opens to a value greater than 0.4Mpa. Compressed air overflow into the clean air chamber to clear the dust on the filter bag; on completion of this action, the poppet valve reopens, the filter cartridge re-opens, and all dust removal actions are completed according to the above procedures one by one.
DECENT MACHINERY FMQD/PPC air box pulse bag filter can provide users with different room numbers and different bag numbers PPC32, PPC64, PPC96, PPC128 and other specifications according to other cleaning conditions You can choose from the following table of specifications. If you need technical assistance, you can call the DECENT MACHINERY service hotline: +86-0533-5201284. After explaining the conditions and your cleaning site needs with our expert and technical staff we will provide you free of charge Provide you with a safe and affordable dust removal solution

Equipment advantage

▲ More convenient control
Adopt PLC program or special pulse controller to control the dust removal, and it can be timed and manual, which ensures the efficient dust removal of the air compressor.
Time description: program the time to automatically clean the dust from room to room
Instructions for use: Automatic control is used during normal working. When a machine has a problem, manual control can be switched randomly to avoid changing the program and causing excessive accumulation of ash in the ash hopper, jamming the drill bit or causing dust to accumulate in the pipeline, reducing suction efficiency and causing damage. pipeline is clogged.
▲ Lower cost
Separate chamber cleaning and spraying: One pulse valve can spray one chamber at the same time (the number of filter bags has specification series 32, 64, 96).Compared with conventional vacuum cleaners Normally, a 6 bag blower valve, the number of pulse valves is reduced from 6-20 times.

 

 